DoS Vulnerability in the Web Connection of DEVELOP Multifunction Printers
Dear Customers,
We deeply appreciate your constant patronage to DEVELOP products.
A vulnerability that allows a Denial-of-Service (DoS) attack has been newly identified in the indicated models. This advisory provides an overview of the issue and the recommended countermeasures.
Please note that, at the time of publication (August 29th, 2025), there have been no confirmed security incidents globally resulting from the exploitation of this vulnerability.
Overview of the vulnerabilities
Ref. ID | CVSSv3.1 | Base Score | Vulnerabilities description |
CVE-2025-54777 | CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L | 4.3 | Importing a malformed file in [Registration of Certification Information] for S/MIME for Email Destination causes the Web Connection to stop. |
Affected Models and the countermeasure firmware
Product name | Affected version | Fixed Version | Latest Version (as of August 2025) |
ineo+ 751i ineo+ 651i/+551i/+451i ineo+ 361i/+301i/+251i ineo+ 4051i/+3351i/+4001i/+3301i ineo+ 3321i ineo 751i ineo 651i/551i/451i ineo 361i/301i ineo 4751i/4051i ineo 4701i ineo+ 750i ineo+ 650i/+550i/+450i ineo+ 360i/+300i/+250i ineo+ 287i/+257i/+227i ineo+ 4050i/+3350i/+4000i/+3300i ineo+ 3320i ineo 950i/850i ineo 750i ineo 650i/550i/450i ineo 360i/300i ineo 306i/266i/246i/226i ineo 4750i/4050i ineo 4700i | G00-RE or earlier | GC2-RE or later (Except G00-RF) | G00-S7 |
ineo+ 759/+659 ineo+ 658/+558/+458 ineo 958/808/758 ineo 658e/558e/458e ineo+ 287/+227 | GCQ-Y2 or earlier | GCR-Y2 or later | G00-YE |
ineo+ 368/+308/+258 ineo 558/458/368/308 ineo+ 3851/+3851FS/+3351 ineo 4752/4052 | GCQ-X4 or earlier | GCR-X4 or later | G00-YE |
ineo 368e/308e | GCQ-X8 or earlier | GCR-X8 or later | G00-YE |
ineo 367/287/227 | GCQ-Y3 or earlier | GCR-Y3 or later | G00-YE |
Impact on Multifunction Printers
Web Connection becomes completely unresponsive. (Other MFP functions are not affected.)
Remediation
The countermeasure firmware will be applied sequentially, either remotely or during the next visit by your authorized DEVELOP service representative.
Vulnerability Specific Recommendation
1. Ensure that the administrator password is secure. If it remains set to its factory default, please change it immediately to a strong complex password.
Configuration: [Utility] - [Administrator] - [Security] - [Administrator Password Setting]
2. Restrict non-Admin users from making any address book destination changes.
Configuration: [Utility] - [Administrator] - [Security] - [Restrict User Access] - [Registering and Changing Addresses]: [Restrict]
General Security Recommendations
To ensure a secure operating posture for your multifunction devices, and to reduce exposure to the vulnerability described in this advisory, DEVELOP strongly recommends applying the following configuration best practices:
Related Information
JVNVU#99831542
Acknowledgements
We would like to express our sincere appreciation to the penetration testers Miguel Alves (0xmupa) for discovering and responsibly reporting this vulnerability
Contact
Should you require further clarification or assistance with implementing the recommended measures or applying the relevant firmware update, please contact your authorized DEVELOP service representative.